   TROUBLESHOOTING GUIDE


Occasionally some circumstance may cause a Blagdon Pump product to malfunction. The following scenarios provide possible solutions to the most common issues experienced with Blagdon Pump products. Before using the Troubleshooting Guide, customers should be aware that most issues with Blagdon products can be solved by routine maintenance, but if the Troubleshooting Guide is still needed then all solutions should be checked before dismantling the pump.

Pump will not start - Erratic Flow - Pump strokes but will not discharge
Fluid Discharged from Air Exhaust - Intermittent Stroke Rate

   SCENARIOS
  PUMP WILL NOT START
CauseSolution
Air valve assembly malfunction / seizureCheck carrier for freedom of movement. Clean, oil and replace.
Obstructed fluid lineClean line or increase line size.
Obstructed diaphragm chamberRemove obstruction
Diaphragm failure causing fluid and excessive air to be expelled through the exhaustReplace diaphragm
Diaphragm seal failureReplace shaft seals
Air valve system malfunctionCheck all seals in valve chest assembly
Air connected to exhaustRe-connect to air inlet
  ERRATIC FLOW
CauseSolution
Diaphragm failure on one sideReplace diaphragm
Valve ball not seatingCheck and remove obstruction
Suction leakageCheck and correct
Diaphragm failure causing fluid and excessive air to be expelled through the exhaustReplace diaphragm
Diaphragm seal failureReplace shaft seals
Air valve system malfunctionCheck all seals in valve chest assembly
  PUMP STROKES BUT WILL NOT DISCHARGE
CauseSolution
Excessive suction liftShorten suction line
Suction line leakageCheck and correct
Valve ball not seating correctly or damagedCheck and remove obstruction / replace
Suction line or strainer cloggedClear
Diaphragm failureReplace diaphragm
  FLUID DISCHARGED FROM AIR EXHAUST
CauseSolution
Diaphragm failureReplace diaphragm
Loose frontplateRe-torque to manual specification
  INTERMITTENT STROKE RATE
CauseSolution
Over lubricationShut down pump. Remove air connection into pump and introduce a small quantity of de-greasing agent into air valve and replace line. Run pump until clear.
Diaphragm shaft seal failureReplace seals
Air valve system malfunctionCheck all seal in valve chest assembly
Valve ball not seating / partially obstructedClear obstruction
  